Implementing Sector:
|
Utility
|
Category:
|
Financial Incentive
|
State:
|
Oregon
|
Incentive
Type:
|
Rebate Program
|
Web
Site:
|
http://www.subutil.com/conservation/for-your-business/
|
Administrator:
|
Springfield Utility Board
|
Start
Date:
|
|
Eligible
Renewable/Other Technologies:
|
-
Heat pumps
-
Programmable Thermostats
-
Windows
-
Roofs
-
Insulation
-
Food Service Equipment
-
Commercial Refrigeration Equipment
-
Attic Insulation
-
Wall Insulation
-
Heat Pump Water Heater
-
Ductless Mini-Split Heat Pump
-
Dual Fuel Air-Source Heat Pump
|
Incentive Amount:
|
- Lighting Retrofit Projects: Minimum $5 per measure (based on 25%+ kWh reduction)
- Lighting New Construction Projects: Incentive based on 20%+ kWh reduction (varies)
- Advanced Rooftop Unit Control (ARC): $120 - $300 per ton of cooling capacity
- Connected Thermostat: $150 initial install, $50 per verification (up to 4)
- Ductless Heat Pump Retrofit: $1,000 per ton
- Air-Source Heat Pump (ASHP) Retrofit: $700 per ton
- Air-Source Heat Pump Upgrade: $150 per ton
- Variable Refrigerant Flow (VRF) System Retrofit: $1,000 per ton
- Variable Frequency Drive on Air Handling Unit Fan: $300 per fan horsepower
- Commercial Packaged Terminal Heat Pump (PTHP): $600 per unit retrofit, $100 new construction
- Demand-Controlled Kitchen Ventilation: $200 - $400 per horsepower
- Heat Recovery Ventilation Equipment: $2.00 - $3.50 per CFM
- Commercial Insulation: $0.80 - $1.90 per sq. ft.
- Commercial Windows Replacement: $3 - $9 per sq. ft.
- Anti-Sweat Heater Controls: $40 - $50 per linear foot
- Efficient Refrigeration Evaporator Fan Motors: $55 - $140 per motor
- Strip Curtains for Walk-In Coolers & Freezers: $9 per sq. ft.
- Refrigeration Floating Pressure Controls: $10 - $20 per MBH
- Refrigerated Display Case Door Retrofit: $100 - $300 per linear foot
- Generator Block Heaters: $200 - $1,500 per generator
- Vehicle Engine Block Heater Controls: $200 per control
- Consumer Heat Pump Water Heater (HPWH): $800 - $1,100 per unit
- Commercial Unitary Heat Pump Water Heater: $2,000 per unit
- Efficient Pumps: $0.33 per kWh saved
- Variable Frequency Drive for Pumps: $180 per horsepower
|
Equipment Requirements:
|
-
Lighting Retrofit Projects
- At least 25% kWh reduction
- Minimum $5 payment per measure
- At least 10% savings per measure
-
Lighting New Construction Projects
- At least 20% kWh reduction from lighting power allowance
- Lighting power allowance based on applicable code or common practice
-
Advanced Rooftop Unit Control (ARC)
- Installed on existing Rooftop Unit (RTU)
- Must be on BPA’s ARC Qualified Products List
-
Connected Thermostat
- Existing thermostat not web-enabled
- Must be web-connected with proper programming
- Verification required after installation
-
Ductless Heat Pump Retrofit
- Existing RTU with ≥ 5 tons cooling capacity
- Constant-speed supply fan
- Primary heating source is electric or gas
-
Air-Source Heat Pump (ASHP) Retrofit & Upgrade
- Installed heat pump must have AHRI certification
- Meets specific HSPF or COP efficiency ratings by size
- Retrofitting zonal or forced-air electric resistance heat
-
Variable Refrigerant Flow (VRF) System Retrofit
- Primary heating source is zonal or forced-air electric resistance heat
- Installed VRF system must have AHRI certification
-
Variable Frequency Drive (VFD) on Air Handling Unit Fan
- Adds variable-speed control to existing single-speed fan
- Disable existing throttling or bypass devices
-
Commercial Packaged Terminal Heat Pump (PTHP)
- Space conditioned by PTAC or zonal resistance heat
- Installed unit must have AHRI certification
-
Demand-Controlled Kitchen Ventilation
- Existing system has constant-speed exhaust fan
- Utilizes control sensors to modulate fan speeds
-
Heat Recovery Ventilation Equipment
- Installed unit must demonstrate ≥ 70% or 82% Sensible Recovery Efficiency (SRE)
- Space conditioned by heat pump or electric resistance heat
-
Commercial Insulation (Heating Zone 1)
- Building electrically heated
- Existing insulation R-value between R-0 and R-5
-
Commercial Windows Replacement
- Electrically heated buildings under 20,000 sq. ft.
- Existing windows are single-pane or double-paned metal frame
- Replacement windows meet SHGC ≤ 0.55 and U-factor ≤ 0.20
-
Anti-Sweat Heater Controls
- Controls reduce heater run time by at least 50%
- Applies to cooler and freezer cases with uncontrolled ASH
-
Efficient Refrigeration Evaporator Fan Motors
- Retrofit shaded pole motors to ECM or PMSM motors
-
Strip Curtains for Walk-In Coolers & Freezers
- Retrofit applications only
-
Refrigeration Floating Pressure Controls
- Floating head and suction pressure controls enabled
- Set points based on ambient temperature
-
Refrigerated Display Case Door Retrofit
- Existing case without doors
- Case served by remote refrigeration system
- New doors must be double- or triple-pane glass
-
Generator Block Heaters
- Forced-circulation block heaters replacing thermosiphon or electric-resistance heaters
- Stationary and fixed generators
-
Vehicle Engine Block Heater Controls
- Hard-wired or engine-mounted thermostatically controlled
- Compatible with 110V resistance immersion heaters
-
Consumer Heat Pump Water Heater (HPWH)
- Retrofit only replacing electric-resistance water heaters
- Must be on BPA’s qualified products list
-
Commercial Unitary Heat Pump Water Heater
- Installed in retrofit or new construction (non-mandatory HPWH areas)
- ENERGY STAR certified with integrated tank
- Installed indoors in conditioned/buffered space
-
Efficient Pumps
- Replaces pumps with PEI between 0.44 and 0.99
- Must be approved pump types (e.g., end suction, in-line, multistage)
-
Variable Frequency Drive for Pumps
- Installed on commercial/industrial single-speed pumps under 100 hp
- Existing throttling/bypass devices disabled
|